[vc_row][vc_column][vc_column_text]Released: 17-03-2017 10:14 CET

Changes in this build

  • #0017 Module Digitize 2D: Tooth templates can be taken over identically from other tracings of the same patient
  • #0039 Module Digitize 2D: Flood filling enabled for tooth templates
  • #3023 Module Segmentation: Gap correction extended for missing teeth
  • #3359 Patch Import: Update bracket list after patch import corrected
  • #3399 VDDS Interface: Transfer analysis results to SoftDent corrected
  • #3470 OnyxPrePrint: Hidden option to cave 3D objects
  • #3642 Export 3D: Fabrication orders: Re-meshing quality can be changed in case of errors
  • #3678 Export 3D: Volume calculation updated after clipping and inserting support
  • #3741 Module Segmentation, Aligner, V.T.O.3D: Gingiva simulation lower jaw improved
  • #3774 All 3D Modules: New default shader for new installations
  • #3819 Warning (Client) in case of critical HD memory for database, pictures and temp folder
  • #3883 VDDS Interface communication: Protocol extended
  • #3941 Module Add Image 3D: ZirkonZahn: Identification upper/lower jaw reviewed
  • #3966 Module Retainer 3D: CAD-Export improved
  • #3986 Module Aligner 3D: Attachment list modified: separate point list per step
  • #4008 OnyxCeph: Help can be opened by menu and shortcut F1
  • #4009 Thumbnail focus kept when leaving module Digitize
  • #4055 Module Image Adjust 3D: Step widths saved
  • #4072 OnyxReport: Workflow for Onyxreport to CD reviewed
  • #4082 Modules V.T.O3D, Aligner 3D: Input of negative tooth limitation values prevented
  • #4096 Full screen: Playing animation adjusted
  • #4149 Command line interface: Language and temp folder added to command line parameters
  • #4177 Calculation of inclination values reviewed
  • #4179 Module Cast Adjust 3D: Single jaw scans can be manually adjusted to base tray
  • #4191 OnyxCeph: Error information extended when loading images in file blobs
  • #4193 All Modules: Available projects can optionally be included in clone finding
  • #4196 Module Aligner 3D: Save as finding: Red colors for violation of movement limitation ignored
  • #4200 Module Add Image 3D: Access violation avoided for corrupt SOP scan files
  • #4203 Tab Presentation: Renaming galleries and gallery templates re-activated
  • #4204 Module Add Image 3D: Handling for occlusion correction restored
  • #4205 Module Add Image 3D: Multiple PLY version support for CS 3600
  • #4211 Module Image Comparison 2D: Option [True to scale] adjusted]
  • #4214 Module Digitize 3D: Bug fix for landmarks on clip planes
  • #4218 OnyxCeph: All Modules 3D: Landmarks displayed in 3D view window
  • #4223 3D Labels: Stability increased for overlapping characters
  • #4224 Module Cast Adjust 3D: Landmarks 13mE|43H resp. 23mE|33H used for jaw alignment
  • #4232 Modules Add Image 2D, 3D: Date/Time filtering implemented for preview panel
  • #4234 Export 3D: Fabrication orders: 3D medical print added to service provider list
  • #4235 Patient list: Bugfix for thumbnail on patient list
  • #4237 Export 3D: Fabrication orders: Column Patienten-ID and Aligner-step number added to basket
  • #4240 Module Add Image 2D: removed drives handled
  • #4242 Print/Presentation editor: 3D views in printouts/slides corrected
  • #4252 Module Sim 3D added
  • #4257 Modules FA_Bonding, Wire_Bonding: Auto adjust improved
  • #4258 Full screen 3D: Button [SPACE] to activated single frame display in video streams
  • #4259 Module Segmentation: Detection of gaps improved
  • #4272 Module Add Image 3D: SOP file import fixed for unicode file names
  • #4273 Module FA-Bonding: Use of single jaws supported
  • #4274 Possibility to open inactive modules removed
  • #4275 Window sequence (tooth movement table) evaluated correctly
  • #4276 PAR Background image adjusted to PAR2 analysis
  • #4281 Module Aligner 3D: Crown navigator adapted for multi selected teeth
  • #4291 Preview for brackets and attachments auto rotating
  • #4292 Parameter Attributes added for finding objects in print/presentation templates

[/vc_column_text][/vc_column][/vc_row]

Similar Posts

  • OnyxCeph³™ 3.1.135 Build 356

    [vc_row][vc_column][vc_column_text]Released: 30-03-2015 14:34 CET Neu in diesem Release #3120 Grafische Auswahl AC für IOTN implementiert #3153 Bracket-Datensätze können ab jetzt archiviert/ausgeblendet werden #3158 Option Reports auf FTP-Server automatisch löschen ergänzt #3159 Fortschrittsanzeige für Arbeitsplatzdateien wird kontinuierlich aktiviert #3162 Brackets laden in Modul Wire_Bonding überarbeitet #3170 Punktauswahl über Doppelklick (IOTN/PAR) #3172 TWAIN-Schnittstelle toleranter gegenüber Vorgabe der…

  • OnyxCeph³™ 3.2.63 Build 142 – Amsterdam

    [vc_row][vc_column][vc_column_text]Released: 01-08-2016 14:31 CET Changes in this build #3366 All 3D-Modules: Calculation of surface piercing landmarks optimized #3801 All 3D Modules: Display of high transparent objects improved #3848 VDDS-Interface: Multiple call PatDat handler on patient data transfer avoided #3886 Several 3D-Modules: Display of findings comparison results corrected #3896 Module Add Image 3D: Multi interface OpenTechDental…

  • OnyxCeph³™ 3.2.66 Build 147 – Helsinki

    [vc_row][vc_column][vc_column_text]Released: 12-09-2016 14:50 CET Neu in diesem Release #3152 Modul Auswertung 3D: Setzen/Verschieben von Punkten kann mit STRG+Z rückgängig gemacht werden #3869 Modul BondingTrays: Alternative Bracket-Fassung flexibler gestaltet, neuer Parameter für Box-Höhe #3909 Modul Aligner 3D: Kronenauswahl im Kontextmenü erweitert #3935 Modul V.T.O.3D: Panel OK/UK: Kein Kontextmenü mehr über der Statuszeile #3977 Modul Bild hinzufügen…

  • OnyxCeph³™ 3.2.40 Build 82 – Lawrence

    [vc_row][vc_column][vc_column_text]Released: 30-11-2015 10:05 CET Neu in diesem Release #2983 Modul Bild hinzufügen 3D: Schnittstelle i/o Scanner 3M True Definition aktiviert #3421 OnyxPrePrint: Druckvorverarbeitung robuster gemacht für Eingabedaten ohne vereinte Vertizes #3428 Modul Bild hinzufügen 3D: Import von OBJ-Daten: Textur-laden korrigiert #3432 Modul Segmentieren: Sonderfälle behandelt #3502 Modul Wire_Bonding: Drahtbogenexport: Export der Bracketslotpositionen #3528 Client-Konfiguration: Globale…

  • OnyxCeph³™ 3.2.126 Build 336 – Pegasus

    Released: 12-08-2019 12:01 CET Neu in diesem Release •#3581 Modul Bild hinzufügen 2D: robustere Erkennung der QR-Codes für die Auswahl des Patienten •#3963 Modul OrthoApps: Modul zur 3D Apparaturenplanung verfügbar •#4384 Modul Waefer Creation 3D: Ausblocken geometrisch robuster und schneller •#4426 Modul Aligner 3D: Serienexport: Werte für beide Kiefer einzeln und Offset der Schrittnummer verfügbar…

  • OnyxCeph³™ 3.2.46 Build 95 – Budapest

    [vc_row][vc_column][vc_column_text]Released: 04-03-2016 14:17 CET Changes in this build #1879 OnyxCeph: Image-/patient data can be read via DICOM from PACS #2475 Systemoptions: Proxy server configuration for downloads added #2513 Modules Aligner 3D/V.T.O.3D: Avoid collision algorithm added in context menu [Move Crowns] #2730 Additional wildcard: Additional Patient ID = %C #2730 Additional wild card: Social Insurance Number…