[vc_row][vc_column][vc_column_text]Released: 18-04-2019 14:54 CET

Changes in this build

  • #0039 Module SIM 2D: Closed contours can optionally be filled
  • #3475 Full screen 3D: Modified object options are kept by animation
  • #4384 Module Waefer3D: Options for vertical block out added
  • #4437 Module Segmentation: Mesh quality on gingiva simulation increased
  • #4452 Module SIM 3D: Dummy button refreshed
  • #4452 Gender Selection: Gender “Diverse/Intersexual” added
  • #4594 Print-/Presentation Editor: Adjusting print objects corrected
  • #4640 ClientSetup: Container file format O3C assigned to OnyxCeph³™ application
  • #4743 Module Digitize 3D: Display of distance lines corrected
  • #4759 Tab Patient: Projects displayed by data
  • #4837 Systemoptions: Configuration for shadow printing available now
  • #4844 Tab Patient: Option for printing a list of patient images acc. to EU GDPR added
  • #4965 Module Cast Adjust 3D: Option to find first contact by jaw rotation added
  • #5060 Print-/Presentation Editor: Page break inserted for long tables
  • #5116 On Shut Down, Onyx is closed w/o confirmation request
  • #5129 Module Digitize 3D: For Image types Cast 3D, panel Occlusogram available now
  • #5172 All 3D Modules: Standard views force camera reset
  • #5174 OnyxSync: Server search window for 2nd server launches with tab |Connection|
  • #5211 Module FA_Bonding: Crown-bracket distance values can be exported in CSV format
  • #5212 Export 3D: Settings can be saved and restored now
  • #5213 Export 3D: Additional object: Hinge guides (acc. to Hinz PA 200 model base trays)
  • #5222 Module FA_Bonding: Brackets can be removed by keyboard button [DEL]
  • #5223 Module Aligner 3D: Tooth movement limitations found for selected crowns
  • #5236 Module Retainer3D: Undo/Redo extended for retainer landmarks #5247 Export 3D: Unterstützung des 3D-Drucks von Bracket-Übertagungsschienen (IBT) durch Dreve
  • #5249 Modules V.T.O.3D, Aligner 3D: Handling for tooth movement tables eased
  • #5252 Print-/Presentation Editor: Display of tooth movement tables in slides corrected
  • #5253 Modules V.T.O.3D, Aligner 3D: Values in tooth movement limitation tables can now be copied and pasted, invalid inputs marked red
  • #5258 Module Aligner 3D: Update of tooth movements on time line slider movement corrected
  • #5260 Module Add Image 2D: Image source dentaleyepad® supported (several adjustments by dentaleyepad pending)
  • #5268 Print Menu: Aktive Übergabe von PDFs an ausgewähltes PVS
  • #5273 Module Aligner 3D: Minimal step distance in time line decreased to allow more planning stages
  • #5277 Module Digitize 2D: Landmark guidance lines not displayed if option is deactivated
  • #5282 Module Add Image 2D: Blue background for mailslot image thumbnails
  • #5283 Print-/Presentation Editor: Adjusting3D objects corrected
  • #5294 Mouse wheel behaviour reactivated for Presentation / Adjust Image
  • #5314 OnyxReport: Message on exit adjusted
  • #5322 Module Add Image 3D: Import problem for CT data from single files fixed
  • #5324 Tab Presentation: Export/Printing of multiple slides with ceph results corrected
  • #5334 Module Aligner 3D: Exchange of initial attachments more consistent now
  • #5337 Modules Add Image 2D/3D: DICOM interface updated
  • #5344 Module Segmentation: Selektion of crown center point keeps already applied gingiva curve corrections
  • #5358 Module Image Comparison 2D: manual modifications of superimposition taken over by separate Angle Society Views